MIL-PRF-49404A(CR)
TABLE V. Environmental inspection procedures.
Req.
MIL-STD-810
MIL-STD-810
MIL-STD-810
Inspection
Para.
Method
Procedure
Remarks
Temperature
3.6.1
503
I
Non-operating mode. Step 2
use -54°C. Step 1 and 4 use
shock
+85°C.
High temperature
3.6.2
501
I
Test simultaneously with
(see Figure 3)
paragraph 3.5.1, for final 30
minutes of step 3. For step 2
use +95°C and steps 4 & 5 use
+71°C
Low temperature
3.6.3
502
I
Test simultaneously with
(see Figure 4)
paragraph 3.5.1, in place of
Table III inspection. For step 2
use -62°C and step 4 use -54°C.
Shock
3.6.4
516.1
IV, V
Non-operating mode.
Vibration
3.6.5
514.1
I, VIII
Non-operating mode. Use
(see Figure 1)
Figure 1 (page 12) in place of
MIL-STD-810 curve.
Sinusoidal cycle time shall be
120 minutes per axis. Dwell
time shall be 1/6 of the cycling
time at each resonance.
6.5 Subject term (key word) listing.
Voltage regulation
Module
Infrared
6.6 Change from previous issue. Marginal notations are not used in this revision to
identify changes with respect to the previous issue due to the extent of the changes.
CUSTODIAN:
PREPARING ACTIVITY:
Army - CR
Army - CR
(Project 5855-0164)
12