MIL-PRF-49040F
c. The output voltage requirements at outputs 5, 6, 7, 8, 9, 12 and 13
(see Figure 2) shall be within the prescribed limits of Table I.
These requirements shall be met when the power supply is operated
with the EGAC at maximum and at minimum gain positions.
3.5.1.1.5.2 High light resolution mode. The output voltages V5 V6, V7, V8,
V9, V10, V12, and V13 shall be as specified in Table II. These requirements
shall be met when the power supply is operated with the EGAC at maximum and
minimum gain positions.
3.5.1.1.5.3
Bright source protection mode.
a. With the EGAC at maximum position, V10 shall not exceed its preset
value of 3.5.1.1.5.1.a by more than 50.0 Vdc.
b. The output voltages V5 V6, V12 and V13 shall be as specified in Table
III. These requirements shall be met when the power supply is
operated with the EGAC at maximum and minimum gain positions.
TABLE I. Output regulation, normal mode
Output
Temperature
Temperature
Temperature
+52oC
+23oC
-54oC
Termina
l
2250 ≤ V5 ≤ 3500 Vdc @ no
2500 ≤ V5 ≤ 3500 Vdc @ no
2250 ≤ V5 ≤ 2500 Vdc @ no
5
load
load
load
1500 ≤ V6 ≤ 2000 Vdc @ no
1600 ≤ V6 ≤ 1900 Vdc @ no
1500 ≤ V6 ≤ 2000 Vdc @ no
6
load
load
load
0.51 V6 ≤ V7 ≤ 0.6 V6 @ no
0.54 V6 ≤ V7 ≤ 0.58 v6 @ no
0.51 V6 ≤ V7 ≤ 0.6 V6 @ no
7
load
load
load
0.8 V5 ≤ V8 ≤ 0.9 V5 @ no
0.84 V5 ≤ V8 ≤ 0.9 V5 @ no
0.8 V5 ≤ V8 ≤ 0.9 V5 @ no
8
load
load
load
0.58 V6 ≤ V9 ≤ 0.67 V6 @ no
0.6 V6 ≤ V9 ≤ 0.65 V6 @ no
0.58 V6 ≤ V9 ≤ 0.67 @ no
9
load
load
load
V10 @ +52oC shall be within
V10 at -54oC shall be
700 ≤ V10 ≤ 1000 Vdc for the
10
within the range of ±20
the range of +25 Vdc and -
loads within the range of 75
20 Vdc of the initial
to 350 megohms.
Vdc of the initial
preset value set at +23oC.
preset value set at
The load shall be 75% ±2%
+23oC. The load shall be
of the load at +23oC.
215% ±2% of the load at
+23oC.
4650 ≤ V12 ≤ 5500 Vdc, and
4800 ≤ V12 ≤ 5300 Vdc for a
4950 ≤ V12 ≤ 5500 and V12
12
at +52oC shall be within
V12 at +52oC shall be
load current less than 40%
±250 Vdc of the preset
within ±250 Vdc of the
Vdc of the ABC start
value at +23oC f or a
preset value at +23oC for
current.
load current less than
a load current less than
40% of the ABC start
40% of the ABC start
current.
current.
5500 ≤ V13 ≤ 6250 and V13 at
5750 ≤ V13 ≤ 6250 Vdc for a
5500 ≤ V13 ≤ 6250 Vdc
13
+52oC shall be within ±250
shall be within ±250 Vdc
load current less than 40%
of the ABC start current.
Vdc of the preset value at
of the preset value at
+23oC for a load current
+23oC for a load current
less than 40% of the ABC
less than 40% of the ABC
start current.
start current.
6
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business