3.10.1 Damage. Breakage, loosening, shifting, evidence of corrosion or
failure of any finish, hardware, connection or component; leakage or
condensation of moisture within the sight; degradation in input or output
characteristics; and any failure of the control knobs to perform their
function.
3.10.2 Zero. A known and specified relationship between the sight
aiming point and the strike of the bullet.
3.10.3 "g". "g" is defined as an acceleration or deceleration of 32.17
feet per second per second.
Room temperature is defined as +23°C, ± 10°C.
3.10.4
Room temperature.
3.10.5 Environmental temperature. Environmental chamber temperatures
shall be controlled to within ± 5°C of the specified temperature unless
otherwise specified.
Illumination levels shall be ±10% of the light level specified.
3.10.6
Tolerance on 2854K color temperature shall be ±200K.
3.10.7
4. VERIFICATION
4.1
Classification of inspection.
Inspection shall be classified as
follows:
a. First article test (4.2)
b. Conformance inspection (4.3).
4.2 First article test (FAT). When specified in the contract or
purchase order (see 6.2.d), first article testing shall be performed by the
contractor. The quantity of first article test samples shall be as specified
in the contract or purchase order (see 6.2.g) and shall be selected from the
first production lot.
4.2.1 FAT testing. Each sight in the FAT lot shall be subjected to the
inspections of Table I. Samples selected from the FAT lot shall be subjected
to the inspections of Table II. Sample size shall be specified in the
contract or purchase order (see 6.2.g). Failure of any inspection shall be
cause for rejection of that sight and may be cause for failure of the FAT.
Inspections may be conducted in any order except for Immersion, which shall
follow temperature extremes and temperature shock.