MIL-PRF-49149D(CR)
2.1.1 Reference documents, drawings and publications. The following
other Government documents, drawings and publications form a part of this
document to the extent specified herein. Unless otherwise specified, the
issues are those cited in the solicitation (see 6.2.d).
DRAWINGS
USA COMMUNICATIONS-ELECTRONICS COMMAND
SM-D-771336 - Electronic Control Assembly
(Copies of specifications, standards, drawings and publications required
by contractors in connection with specific procurement functions should be
obtained from the procuring activity or as directed by the contracting
officer.)
2.2 Order of precedence. In the event of a conflict between the text
of this document and the references cited herein, the text of this document
takes precedence. Nothing in this document, however, supersedes applicable
laws and regulations unless a specific exemption has been obtained.
3. REQUIREMENTS
3.1 Description. The electronic control is mounted to and limits
operation of the Viewer, Driver's Night Vision AN/VVS-2(V) under damaging
light brightness level.
3.2 Construction. The electronic control shall be constructed to
assure compliance with the contract configuration baseline and in accordance
with SM-D-771336 as applicable.
3.3 First article testing (FAT). When specified in the contract (see
6.2.c and 6.2.f) the contractor shall furnish units for FAT inspection and
approval (see 4.2).
3.4 Materials. The contractor shall select parts and materials that
are fully capable of meeting all of the operational and environmental
requirements specified herein. The materials specified in the applicable
drawings are recommended, but not mandatory. Selection criteria of the class,
grade or type part shall ensure the material will be able to perform its
intended function when it is assembled. Verification of the supplier meeting
the overall performance requirements shall be the governing acceptance
standard. Recovered materials shall be used to the maximum extent possible.
3.5
Performance characteristics.
NOTE: The performance tests of 3.5 shall be performed with a 51 ±2
ohm load between pins 1 and 4 of the electronic control.
3.5.1 Power output. When the photo-detector is blocked, the electronic
control shall be within ±0.3 Vdc of the input voltage when energized with a
BA-5567/U battery, or equivalent DC power source.
3.5.2 Power cutoff. The output voltage of the electronic control shall
be reduced to 0.2 Vdc or less when the photodetector views a bright target
area between 0.1 and 0.18 footlamberts.
3.5.3
Power restoration.
Output voltage shall return to within + 0.2
2
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business