MIL-PRF-49170B(CR)
TABLE V. Environmental inspection procedures.
Req.
MIL-STD-810
MIL-STD-810
MIL-STD-810
Inspection
Para.
Method
Procedure
Remarks
High temperature
3.6.2
501.1
I
Storage temperature (Step 2)
shall be +68° for 6 hours
(storage)
duration.
Low temperature
3.6.3
502
I
Storage temperature of Step 2
shall be -51°C for 9 hours. Step
storage
5, "operate", shall be the ability
to meet the requirements of the
specification.
Step 1 & 4 shall be +68°C and
Temperature
3.6.1
503.1
I
Step 2 shall be -51°C.
shock
Transition from 65°C -51°C or
visa versa shall include a 2 hour
stabilization period @ 23°C.
Vibration
3.6.5
514.2
VIII
Use curve V as an alternative
use method 201A of MIL-STD-
202.
Shock
3.6.4
516.2
II
Time duration: 4 milliseconds
Altitude
3.6.6
500.1
I
Operation @ 40,000 feet above
sea-level
6.4 Definitions.
6.4.1 Damage. Breakage, loosening, shifting, evidence of corrosion, or failure of any
finish, hardware, connection or component; and any degradation of imager performance to
values less than specified herein.
6.4.2 Ambient temperature. Ambient temperature is considered to be +23°C, ± 5°C.
6.5 Subject term (key word) listing.
Detector Array
6.6 Changes from previous issue. Marginal notations are not used in this revision to
identify changes with respect to the previous issue due to the extent of the changes.
CUSTODIAN:
PREPARING ACTIVITY:
Army-CR
Army-CR
(Project 5855-0095)
12
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business