MIL-PRF-49319A(CR)
TABLE I. Inspections.
Inspection
Requirement paragraph
Dimensions not as specified
3.3.1
Any as specified part or component
missing or damaged
3.3.1
Weight not specified
3.3.2
Getters and label not
as specified
3.4
Detector-Dewar orientation range
not specified
3.4
Sensitive area not as specified
3.5.3
Detector-Dewar warm and cold shields
not as specified
3.5.11
Treatment and painting
not as specified
3.8
Marking not as specified
3.10
Workmanship not as specified
3.11
4.2.2 Tests. First article inspection shall be conducted upon units which have successfully
completed the inspections specified in 4.2.1. Tests may be conducted in any order, except that the
microphonics inspections shall be performed after shock and vibration tests have been completed
(see 3.6.4 and 3.6.5).
9
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business