MIL-PRF-49384B(CR)
6.3.2 Ambient temperature. Ambient temperature is defined as 23 degrees centigrade.
6.4 Environmental inspection procedures. The test methods and procedures of
MIL-STD-810, listed below, are recommended, but are not mandatory for determining
compliance with the environmental requirements of this specification.
TABLE V. Environmental inspection procedures.
Remarks
MIL-STD-810
MIL-STD-
Inspection
Spec
Method
810
paragrap
Procedure
h
Steps 1 & 4 shall be +71°C
Temperature shock
3.6.1
503.1
I
and Step 2 shall be -54°C.
Transition form +71°C to -
51°C and from -51°C to
71°C shall include a 2 hour
stabilization period at
+23°C.
High temperature
3.6.2
501.1
I
Storage temperature (Step
2) shall be +95°C and
operation temperature shall
be +71°C. Test shall be for
6 hours.
Low temperature
3.6.3
502
I
Storage temperature (Step
2) shall be -62°C for 9
hours. Step 4 for operation
shall be -54°C for 9 hours.
Shock
3.6.4
516.2
II
Time duration is 11
milliseconds.
Vibration
3.6.5
514.2
VIII
Use Curve V. Use Method
201A of MIL-STD-202 as
an alternative. (See Figure
3).
Altitude
3.6.6
500.1
I
Operator altitude chamber
@ 10,000/ft above sea level
for operation and 40,000
feet above sea level (Step
2) for 3 hours.
6.5 Subject term (key word) listing.
Detector array
Mechanical scanner
Infrared system