MIL-PRF-49177B(CR)
b. Conformance inspection (see 4.4)
4.1.1 Inspection parameters. Unless otherwise specified, the Scan-Interlace (PL-
1408/UA) shall be tested at 42 Hz (see 6.2).
4.2 First article inspection. When specified in the contract, the first selected number of
first article inspections shall be performed by the contractor on a sample unit (see 3.1). First
article reliability testing per 4.7 will not be required unless specified in the contract or purchase
order.
4.2.1 Inspections. All materials, parts, processes and assemblies shall be visually
examined for conformance to the applicable specification or drawing. Inspections shall be made
using ANSI/ASQ Z 1.4 sampling procedures. ASTM E 122 sample sizes shall conform to 89 as
cited in the contract or purchase order.