MIL-PRF-49168C(CR)
4.3.5 Impedance. The supply output impedances shall not be greater than 0.1 ohm to 10
kHz and 5 ohms to 100 kHz.
4.4 Conformance inspection.
4.4.1 Visual inspection. Inspection shall be the same as specified in 4.2.1.
4.4.2 Tests.
4.4.2.1 Group A inspection. Group A inspection shall be conducted at an ambient
temperature of (see 6.4.2) on all Scan-Interlaces following the preconditioning of 4.8 and the
inspection 4.4.1. Group A tests may be performed in any order. Failure of any test shall be
cause for rejection of the unit.
10
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.