MIL-PRF-49168C(CR)
TABLE III. Group A inspection.
Scan-Interlace
PL-1403/UA or PL-1403A/UA
Inspection
Reqt
Test
Adjustment
Pins
para.
para.
during test
tested
Power consumption
3.5.1
4.5.1
None
None
Identification resistors
3.5.2
4.5.2
None
P1-4, P1-16
P1-6, P1-16
± 3.4 Vdc regulator
3.5.3
4.5.3
+REG R6
+J1-8
-REG R7
P2-14
voltage
+J1-11
P2-14
Transducer bridge
3.5.4
4.5.4
XDCR BR
J1-17(+)
voltage
R14
PL-1403/UA
J2(+)
PL-1403A/UA
P2-14(-)
Scan motor drive
3.5.5
4.5.5
Scan speed
J1-18
waveforms
R24
J1-19
Interlace position
3.5.6
4.5.6
None
J1-1 or J3
amplifier waveform
Position reference
3.5.7
4.5.7
Pos. error
J1-2
waveform
gain R46
Position error
3.5.8
4.5.8
Pos. error
J1-5
waveform
gain R42
Rate reference
3.5.9
4.5.9
Pos. error
J1-12 PL-1403/UA
waveform
gain R65
J1-9PL-1403A/UA
Solenoid drive
3.5.10
4.5.10
Bal R64
J1-3
waveform
J1-4
Video gate width
3.5.11
4.5.11
Gate width
J1-14 PL-1403/UA
R57
J1-7 PL-1403A/UA
Side/rear phasing
3.5.12
4.5.12
None
J1-3
J1-13
J1-14
4.4.2.2 Group B inspection. Not required.
4.4.2.3 Group C inspection. Group C inspections shall be conducted on assemblies
selected from units which have passed the tests in 4.4.2.1. The sample (s) shall be subjected to
the inspection listed in Table IV. Samples shall be selected in accordance with the contract or